HUIM6 Successful PMU: Milestone Achieved!
Air Infiltration/Exfiltration Test…✔️PASSED
Water Penetration Test…✔️PASSED
Impact Resistance - Soft and Hard Body…✔️PASSED
We are thrilled to announce the accomplishment of the PMU Testing for the Mohammed VI International University & Hospital project using WICONA Middle East system.
The test has passed in all parameters from the first attempt, and we're ready to proceed with our works!

An additional scope has been awarded to                                              Glassline                                               for                                              Jawharat Al Riyadh Mall                                               project.                                              Glassline                                               has been entrusted with the                                              Design, Engineering, Fabrication, and Supply                                               of the                                              11,500 m² Roof Skylight                                               (single-layer structure & glass) and the                                              Funnel                                               (single-layer structure without glass) in the                                              Volcano Area                                               . This includes the                                              Single Layer Structure CSL system                                  , along with aluminum profiles, nodes, connections, and all essential fixing components.
 

Our custom-designed façade for the Normans Cay project, successfully passed the Miami-Dade Test, meeting and exceeding the stringent Florida hurricane resistance standards!                                                                  The testing was done at Blackwater Testing Facility in Italy, where our façade underwent simulations of nature’s extreme conditions:                                                                                                            💥 Missile impact on glass and aluminum                                                      🌀 Static and cyclic loads (9,000 cycles of positive and negative pressure)                                                      🌊 Air and water penetration                                                      💨High-velocity winds                                                      🔒 Forced entry after glass breakage
 

The performance mock-up of the PDP3 Project has successfully passed all dynamic and static tests in  Farabough Engineering USA, outperforming in some instances the test requirements. In particular, during the Dynamic Seismic test done according to AAMA 501.4, our facade reached an ultimate value of 150mm, whereas the requirements stipulated 25mm left-back to position-25mm right-back to position.
 